Application:
It has been widely used in LPG transfer in wharves.
Characteristic:
- End fitting materials for low temperature service
- Reinforced lining applied along the hose bore to reduce the risk of explosive decompression
- May include a butterfly valve, camlock and/or light blind flange.
- Hose will be fitted with a spool piece at both ends equipped with lifting lugs for easy material handling.
- Hoses equipped with suitable rubber collars capable of preventing mechanical wear to external body of hose under all.
- The Hose Shall be marked “LPG” per 10 ft interval accoring to API 2510
Acceptance criteria:
Acceptance criteria for -50˚C operation included the following:
Long term LPG soak test
Gas permeation and decompression test
Thermal insulation test
Thermal cycling test
Fatigue testing
Temperature: -50℃ to +50℃
Certification: OCIMF